CCYTD - SOLUTION S0447 LH-3 TITRANT LO

  • MSDS: CCYTD
  • Manufacturer: NALCO CHEMICAL CO
  • Product Name: SOLUTION S0447 LH-3 TITRANT LO
  • National Stock Number: 6850-00N076195
Product Identification

Product ID:SOLUTION S0447 LH-3 TITRANT LO
MSDS Date:08/23/1995
FSC:6850
NIIN:00N076195
MSDS Number: CCYTD

Responsible Party
NALCO CHEMICAL CO
ONE NALCO CENTER
NAPERVILLE, IL 60563-1198
US

Emergency Phone: 800-462-5378

Info Phone: 708-305-1000

Preparer: WILLIAM S UTLEY

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

NON-HAZARDOUS INGREDIENTS

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY SYMPTOMS FROM EXPOSURE NOT PREVIOUSLY MENTIONED.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: FLUSH CONTACTED AREA WITH WATER. EYES: FLUSH WITH
POTABLE WATER FOR AT LEAST 15 MINUTES. SEE MD . INHALATION: REMOVE
TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN OR ARTIFICIAL
RESPIRATION) . INGESTION: CALL MD IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NOT APPLICABLE. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH TO LABORATORY DRAIN OR SEWER WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT TAKE INTERNALLY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION IS NOT NEEDED. USE NIOSH
APPROVED RESPIRATOR FOR EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION IS RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Solubility in Water:COMPLETELY
Appearance and Odor:COLORLESS, ODORLESS LIQUID

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NOT APPLICABLE.

Disposal

Waste Disposal Methods:FLUSH TO LABORATORY DRAIN OR SANITARY SEWER WITH
WATER. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.